  • Guidelines for Setting User Relay Protection

    Guidelines for Setting User Relay Protection

    This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution. Applications range from classic panel built control systems to modern interfaces between control microprocessors and their power circuits or any application where reliable galvanic separation is required between different circuits. Altough. Protective relays and devices have been developed over 100 years ago to provide “last line” of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Many important issues, such as coordination of settings, operating times, characteristics of. Fingrid's application guideline for relay protection presents the operating principles of the relay protection in Fingrid's 110, 220 and 400 kV power networks and the requirements for operation of the protection systems of Fingrid customers (hereinafter referred to as 'customer').

    [PDF Version]
  • Standard Requirements for Wiring in Landscape Distribution Boxes

    Standard Requirements for Wiring in Landscape Distribution Boxes

    NEC Requirements for Outdoor Distribution Boxes: Complete specification guide for outdoor electrical distribution boxes covering NEC Article 312 requirements, NEMA ratings, sizing calculations, and selection criteria for commercial and residential applications. Meets Code Requirements: NEC Article 314 mandates that all electrical connections outside the protective sheathing of cables must be housed in approved boxes. Installing without proper junction boxes is a code violation. 💡 Specification Insight: NEC 312. If it's done poorly, you risk short circuits, fire hazards, or system failure. Done right, it ensures safety, compliance, and long-lasting performance. In this guide, we'll break down everything you need to know to install. ⚡ Safety First Always disconnect power before inspecting wiring. Article 314 applies to: These.

    [PDF Version]
  • How to connect the secondary wiring of the primary cabinet

    How to connect the secondary wiring of the primary cabinet

    Primary: Pass the main live phase cable through the CT window (Source entering P1 side). Connect wire from S1 (k) to the Meter Current Input (+) or k. Always ground one side of the CT secondary (typically S2). We'll cover how to connect the primary and secondary windings based on your specific voltage requirements and highlight crucial safety precautions to follow during the process. This prevents the secondary. Construct control cabinets in a fraction of the time through simple manual wiring without tools: WAGO Push-in CAGE CLAMP ® Technology allows you to reduce costs, increase the safety of your application and reduce the time and effort for control cabinet wiring by up to 50 percent. If a CT must be installed without the secondary wiring connections made, a shorting link should be. Without an upstream LINE-SIDE OCPD as explained above, often smaller phase wires terminating directly to transformer secondary terminals x1 and x2 and now become TAPS. 21 such as limited to 10' spans. The following is a detailed introduction to it: - **Familiarize with Drawings**: Carefully study relevant drawing materials such as electrical schematic.

    [PDF Version]
  • Red and Green Optical Cable Wiring Sequence

    Red and Green Optical Cable Wiring Sequence

    Under the TIA/EIA-598-C standard, the universal 12-color sequence is: 1-Blue, 2-Orange, 3-Green, 4-Brown, 5-Slate (Gray), 6-White, 7-Red, 8-Black, 9-Yellow, 10-Violet, 11-Rose, and 12-Aqua. This sequence repeats for cables with more than 12 fibers. Global Consistency: Whether cables originate in North America, Europe, or Asia, the same 12‑color sequence applies—so any technician can interpret it correctly. * For cables >12 fibers: The sequence repeats with one or more black stripes (except black fibers, which receive yellow stripes) to. Individual fiber strands within multi-fiber cables follow a standardized 12-color sequence that enables precise identification during splicing, termination, and troubleshooting operations. This systematic approach supports accurate fiber management in high-density installations. These colors are used to identify individual strands inside fiber optic cables. Using proper color coding makes installation easier, speeds up troubleshooting, reduces downtime, and supports future network.

    [PDF Version]
  • Charging pile wiring should be routed through public cable trays

    Charging pile wiring should be routed through public cable trays

    Indoor cable lines should preferably be laid in cable trays or conduits; outdoor cable lines should preferably be laid in cable trenches or buried in protective conduits. The protective conduits should meet the requirements for pressure resistance and environmental corrosion. Medium and low voltage power distribution systems should preferably use single busbars, single busbar sectionalized systems, or cable wiring. However, any installation must adhere strictly to the National Electrical Code (NEC) standards. Here is the summary of the main points found in NEC Article. This article explains the main requirements and good practices for cable tray systems, including tray types, materials, loading, supports, bonding, cable selection, and installation details. The content is written to be SEO-friendly and compatible with Yoast SEO for WordPress.

    [PDF Version]
  • 180 Network Patch Panel Wiring

    180 Network Patch Panel Wiring

    Learn the step-by-step network patch panel and keystone jack wiring methods, including essential tools, T568A/B wiring sequences, and tool-free installation tips. This guide covers everything you need for efficient network setups, from cable preparation to final. Both work on the same principle, using the module's built-in clips to press the network cable directly into the module's wire clamps, eliminating the need for punching down steps. (*Our company's account name is " Cobtel Precision Electronics Co. " Please carefully verify beneficiary's name. Centralized Organization: A network patch panel serves as a passive, centralized hub that connects long cable runs to your active network switches. T568B is the. When you're building a network, it's often ideal to use a patch panel to direct cables and organize long Ethernet runs — especially if they go through walls, floors, and/or ceilings. They come in a range of sizes, and are typically mountable, whether that's on a wall, or on a rack to make for easier.

    [PDF Version]
  • Fire alarm control distribution box power failure

    Fire alarm control distribution box power failure

    Power-related issues are among the most critical faults in fire alarm control panels. Every commercial fire alarm panel is required to maintain both primary (AC mains) and secondary (battery) power sources. When the panel detects voltage irregularities, it generates a power supply trouble signal. Diagnosing power supply troubles is not always straightforward, as these issues can manifest in various conditions displayed at the panel. Some problems are clear-cut, such as an illuminated “Battery Trouble” LED or the absence of a green “AC On” light. But what should you do if there is a fault in the fire alarm. When a fire alarm panel system trouble signal activates, it indicates that a non-fire fault condition exists within the fire alarm system, signaling that a component or circuit isn't functioning as intended and requires investigation and repair to maintain full operational readiness.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +27 82 415 6793
Address Unit 7, Innovation Park, 34 Electron Road, Kempton Park, 1620, South Africa